Instrument introduction
1, Simultaneous analysis and measurement of multiple elements (any number of elements from Na to U);
2, the use of phototype design, completely avoid pollution and damage to the detector, no maintenance, to ensure the safety of the instrument;
3, non-destructive analysis of the sample, accurate and fast analysis;
4, automatic mechatronics design, stable and reliable operation of the instrument;
5, the sample plate automatically rotates, the measuring area is larger, and the particle error and uneven error can be eliminated to the maximum extent (optional);
6, the use of electric control multi-link system, single sample automatic sampling detection, easy to operate, the use of multi-layer protection completely shield X-ray radiation to the human body;
7, the use of high-quality temperature control system, the instrument is not sensitive to external temperature changes;
8, the use of SDD detector (the United States, Germany optional), analysis speed, high accuracy, good stability, low failure rate;
9, WINDOWS system under the Chinese and English operating software, convenient for domestic and foreign users. Operators of different proficiency levels can call the relevant help menu at any time to guide the operation of the instrument.
Specifications
| excitation system | voltage | 6kV-50kV continuously adjustable |
| max power | 50W | |
X-ray tube type | Side-window and end-window | |
| target material | Rh,Ag, W, Mo, Pd, Ti,etc. | |
| parameter settings | integrated and adjustable filament power with consistent and adjustable voltage and current; protection for over electrical force and current | |
excitation source | low ripple , high stability | |
| sample feeding system | method | servo motors and stepper motors |
| quantity | samples are placed one at a time | |
| protection | a special protection device is in place to ensure safety | |
| detection system | SDD detector (optional in USAand Germany) | |
user-friendly with high resolution, high count-rate, high stability and high compatibility | ||
super-thin C window can define the peak of F | ||
auto light collimation and filtration system | shaft-driven fan embedded with four filters | |
auto control system | advanced anti-jamming chip | |
| highly-reliable driver circuit | ||
| highly-precise A/D converter | ||
| others | application | Quartz sand, glass, ferroalloy, inoculant, catalyst, corundum materials, non-metallic ore, brown corundum, thermal insulation materials, spheroidizing agents, refractory materials and raw materials, etc. |
| sample state | powder, solid | |
| advantages | high stability, low LOD, full wavelength and lossless analysis | |
| dimensions(mm) | 550*520*1150 | |
environmental requirement | T 5℃-30℃ H 20%-80% | |
| weight | 110KG | |
| V/F | AC220V±10%/50Hz | |
| power | max 3KVA standby 0.6KVA | |